Customization: | Available |
---|---|
After-sales Service: | Guide Installation or Video Debugging |
Warranty: | 5 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Vacuum Autoclave for Composites Carbon Fiber Curing Oven Prepreg Autoclave Fiberglass Autoclave Kevlar/Aramid Fiber Autoclave Epoxy Resin Curing Autoclave
Composite Oven Carbon Fiber Composite Autoclave For Wing/Fuselage/Engine Blade Prepreg Autoclave refers to a kind of equipment used in the aerospace and other industries to process carbon fiber composite materials into components such as wings, fuselages, and engine blades.Description | Unit | Specifications And Parameters |
Working Diameter | mm | 1200 |
Working Length | mm | 2400 |
Max. Working Pressure | bar | 25 |
Max. Working Temperature | ºC | 400 |
Max. Pressurization Rate (Average) | Bar/min | 0-1 |
Max. Depressurization Rate (Average) | Bar/min | 0-1 |
Max. Heating Rate(Air Average) | ºC/min | 0-3 |
Max. Cooling Rate (Air Average) | ºC/min | 0-3 |
Temperature Uniformity At Steady State | ºC | ≤±21 |
External Shell Temperature At Max. Temperature | ºC | ≤55 |
Quick Openning Door Mode | - | Hydraulic Door Opening |
Working Medium | - | Compressed Air Or Nitrogen Pressurization |
Heating Mode | - | Stainless Steel Electric Heating |
Quantity Of Circulating Fan Motor | SET | 1 |
Thermocouple Type | - | Type K Or J |
Vacuum Ports | PIECE | 8 |
Min. Vacuum Pressure | bar | -0.09 |
Standard Control Mode | - | PLC Logic Control |
Insulation Form | - | Internal Insulation |
Exterior Color | - | Customized |
1. Are you a trading company or a manufacturer?
We are a production factory, with 20 years of experience in design and production, we can customize the right equipment for you according to different process requirements of different products.
2. What is the difference between an autoclave and an ordinary oven?
Autoclaves can control temperature, pressure and vacuum at the same time, while ordinary ovens only heat. High pressure environment can reduce material porosity, improve strength, suitable for high performance composite materials.
3. What are the key technical parameters of autoclave?
Temperature range: Usually 100°C - 200°C (depending on resin type).
Pressure range: 0.5MPa - 1.5MPa.
Vacuum degree: close to -1bar (excluding air).
Cavity size: customized according to product size (such as aviation grade tank diameter up to 6 meters).
4. How to choose the right autoclave?
To consider:
Product size and yield.
Material type (resin curing temperature, pressure requirements).
Accuracy requirements (temperature uniformity, pressure stability).
Budget and energy efficiency (e.g., energy-efficient heating systems).
5. Is the autoclave expensive to maintain?
Maintenance costs depend on frequency of use and maintenance specifications. Check seals, pressure sensors, and heating elements regularly to avoid leaks or temperature deviations. Long-term maintenance can extend the service life of the device.
6. What are the safety measures for autoclaves?
Pressure relief valve prevents overpressure.
Multiple temperature monitoring to avoid overheating.
Explosion-proof design and emergency stop system.
Operators must receive professional training.
7. Can autoclaves handle composite materials of different thickness?
Yes, but the process parameters need to be adjusted. For example, thick-walled parts may require longer curing times or stepwise heating to avoid uneven resin curing.
8. What is the difference between autoclave and vacuum bag forming process?
Autoclaves increase material density through external pressure, while vacuum bags rely only on atmospheric pressure (about 0.1MPa). Autoclaves are suitable for high performance, large size components, and vacuum bags are mostly used for low cost or small batch production.
9. What is the energy consumption of autoclaves?
Energy consumption is high (especially for large equipment), but costs can be reduced by optimizing processes (such as reducing heating times) and using energy-saving technologies (such as infrared heating).
10. How to ensure a uniform temperature in the autoclave?
Use circulating fan or hot air flow design.
Calibrate the temperature sensor regularly.
Place components properly (avoid blocking air outlets).
11. Can autoclaves be used to recycle carbon fiber composites?
At present, it is mainly used in the manufacture of new materials. Recovery requires chemical or mechanical separation of the resin from the fiber and is not directly related to the autoclave process.
12. Typical failure and solution of autoclave?
Insufficient pressure: Check seals or vacuum pumps.
Temperature fluctuations: Calibrate the heating system or replace the sensor.
Vacuum leak: Locate the leak with a leak detector and repair it.